Adsorption Analyzer
Your Professional Adsorption Analyzer Supplier
Quzhou Zhongyi Chemicals Co., Ltd. is specialized in manufacturing pumps and valves. We are supported by an experienced technical team, machining workers and strict inspection to offer various products with competitive prices and reliable quality.
Main products
B series submersible sewage pumps, AST building civil dedicated sewage pump series, FH series fountains, garden dedicated pumps (stainless steel), WQ pumps, QW series submersible sewage pumps, ISWD series horizontal centrifugal pumps, DL Vertical Multistage Pumps, GDL type multi-stage pipeline pumps, multi-stage water pumps, complete life (fire) water supply equipment, frequency conversion control cabinets, control cabinets and other special pumps.
-
Bet AnalyzerThe BET Analyzer measures specific surface area and porosity, critical physical parameters of porous materials typically assessed through physical adsorption methods. Under controlled conditions,...read more
Why choose us
Certification
All our products are independently developed and produced, and have passed the national compulsory product certification, non-negative pressure water supply equipment test report, and ISO9001, CQC and other international standard certifications.
ODM and OEM services
We are specialized in the RD, Manufacture and Sales of submersible water pumps & spare parts. We provide ODM and OEM customization services to meet the unique needs of our clients.
Sales Market
Our products have successfully been exported to over 100 countries and regions, including Southeast Asia, Europe, Africa, South America, Oceania, and North America, establishing a solid reputation for excellence within the domestic submersible pump industry.
After-sale service
We have a complete after-sales service system, so you can purchase with confidence.
Specifications
|
Control Mode |
Automatic controlled by software |
|
Communication mode |
RS485, upgraded to the USB or network interface |
|
Built-in Detector |
Three pressure sensors, including a pressure sensor of pirani vacuum silicon |
|
Analysis station |
1~3 |
|
Volume of sampling |
0.1-3mL |
|
Reaction Gas |
N2, Ar,CO2 |
|
Gas Purity |
>99.995 % |
|
Calibration Gas |
He |
|
Control of Gas Flow |
PID |
|
Sample Cell |
Erect type, quartz material, half- round bottom |
|
Degassing Station |
1-3 degassing stations of built-in,6 degassing stations of external sample cell. |
|
All in One Valve Unit |
Integrated valve bank, pile-up valve, gas circuit, pressure sensor |
|
Vacuum System |
Two-stage rotary vacuum pump, turbo molecular pump if necessary |
|
Vacuum Purity |
1*10-2 pa, 1*10-6 pa can be reached if on the condition of molecular pump |
|
Dewar |
2L-4L high capacity, staying warm is no more than 100 hours |
|
Jacking System |
Automatically controlled by lift |
|
Software |
Dedicated analysis workstation of software,based on Windows platform software |
|
Data Export |
Support TXT text output,which makes the exchange data with drawing tools like Origin more convenient |

Vacuum volumetric method for specific surface area and porosity analysis. Complies with national standard GB/T 19587-2004.
- Suitable for measuring specific surface area and porosity of pores or micropores, with a fully automatic measurement process
- Intelligent gas system automatically selects refined or rough gas intake modes to optimize analysis precision and efficiency
- High vacuum system with maximum vacuum degree up to 10-6 Pa
- Precise pressure control via servo valve and magnetic valve
- High thermal insulation dewar with temperature protection jacket for enhanced heating preservation effect
- Pirani vacuum gauge sensor ensures accurate measurement under high vacuum pressures
- Various optional gas and bath analysis methods in cold environments
Limitations
Pore Size Distribution
While it can determine surface area accurately, BET analysis might not provide detailed information on the distribution of pore sizes.
Assumption of Ideal Monolayer
The method assumes the formation of an ideal monolayer of adsorbed gas molecules, which might not hold true for all materials, impacting accuracy.
Sample Preparation
Sample preparation is critical, and factors such as surface cleanliness and proper degassing can affect the results.
Limited to Specific Materials
The applicability of BET analysis is limited to materials that exhibit physical adsorption characteristics with the gas used for measurement.
Applications
》Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.
》Product quality control for powder materials related corporations.
》Research institutes, universities for BET theory teaching.
》Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.
》Other researches concern surface area performance.
Performance Indicators
Test function:Static volumetric principle,adsorption/desorption isotherms measurement,single and multi-point BET method,Langmuir method, BJH total pore volume and pore size distribution analysis,DR and DA filling theory, t-plot external surface area measurement,true density measurement;powerful online data analysis system and specific surface area and pore size distribution test system to ensure more stable and accurate test data.
Sample number:Two samples tested at same time and two samples’ degassing treatment,the sample testing system and sample processing system are independent; sample testing and sample processing can be carried out simultaneously, avoiding the contamination of the test pipeline, further ensuring the accuracy of the test and improving the service life of the instrument.
Test mode:Integrated "Single nitrogen test mode" and "Nitrogen + helium standard test mode", for customers to choose according to actual needs;using "Nitrogen + helium standard test mode" in line with international standards, can ensure the accuracy and consistency of results, and easy to operate;for samples that can adsorb helium at low temperature, helium gas is not suitable for determination of free space,"Single nitrogen test mode" can get the desired test results.
Test gas:High purity N2gas or other (Ar, Kr are optional)
Vacuum pump:Imported two-stage vacuum pump can be external and built-in; the built-in vacuum pump can be automatically controlled by the software according to the experimental needs, so as to extend the life of the vacuum pump.
|
Test ranges |
0.0005 (m2/g)~no known upper limit (specific surface area);2nm-500 nm |
|
Test accuracy |
Specific surface area repeatability error ≤±1.0% |
The high vacuum micro welding pipeline system has compacted pipeline connection and small dead volume space VCR interface parts with metal surface seal overcome the problem of self outgassing of O-ring seal under low vacuum.
The supporting VCR interface pneumatic valve eliminates the measurement error caused by local heating of the electron magnetic valve.
The electropolished method of pipe wall in the whole system ensures the air leakage rate to reach the requirements of 1 * 10-10pa.m3/s under high vacuum.

Digital pressure measurement and data acquisition system
The pressure and temperature sensor with digital output has twice the accuracy of similar products with analog output and stronger anti-interference ability.
Industrial standard RS485 or RS232 communication mode, sensors are added on demand on the communication bus, with high scalability.
The high-precision digital pressure sensor has a pressure output resolution of 1Pa, conducive to improving the test accuracy compared with the 4pa resolution commonly used in the same industry.
Certificates



FAQ
As one of the leading adsorption analyzer manufacturers and suppliers in China, we warmly welcome you to buy cheap adsorption analyzer made in China here from our factory. All customized pumps and valves are with high quality and low price. For quotation, contact us now.
uv sterilizer, flow meter, mixer
